{"id":7195,"date":"2026-06-05T20:13:15","date_gmt":"2026-06-05T20:13:15","guid":{"rendered":"https:\/\/www.jagalcaide.com\/caldera-sime-error-all-02-solucio\/"},"modified":"2026-06-05T20:13:18","modified_gmt":"2026-06-05T20:13:18","slug":"caldera-sime-error-all-02-solucio","status":"publish","type":"post","link":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/","title":{"rendered":"Caldera Sime error ALL 02: Causes i solucions definitives"},"content":{"rendered":"<p>En ple descens de les temperatures, la fiabilitat del confort t\u00e8rmic a la llar esdev\u00e9 una prioritat absoluta. Trobar el codi d&#8217;error &#8220;ALL 02&#8221; parpellejant al display d&#8217;una caldera Sime \u00e9s una situaci\u00f3 que genera una preocupaci\u00f3 l\u00f2gica, especialment perqu\u00e8 acostuma a interrompre immediatament tant el subministrament d&#8217;aigua calenta sanit\u00e0ria com la circulaci\u00f3 del circuit dels radiadors. Aquest mecanisme de bloqueig preventiu \u00e9s un dels avisos de seguretat m\u00e9s habituals que detectem als habitatges durant la temporada de major exig\u00e8ncia t\u00e8rmica.<\/p>\n<p>Segons les directrius de resoluci\u00f3 d&#8217;anomalies detallades al manual d&#8217;instruccions oficial de les calderes Sime, aquesta alerta alfanum\u00e8rica adverteix concretament sobre una caiguda acusada de la pressi\u00f3 de l&#8217;aigua a l&#8217;interior de la instal\u00b7laci\u00f3. Perqu\u00e8 l&#8217;equip ofereixi un rendiment \u00f2ptim i sense riscos, la pressi\u00f3 del circuit tancat s&#8217;ha de situar entre 1 i 1,2 bars estant la m\u00e0quina en rep\u00f2s i en fred. El control rigor\u00f3s d&#8217;aquests par\u00e0metres t\u00e8cnics \u00e9s fonamental i s&#8217;alinea de manera directa amb els est\u00e0ndards promoguts per l&#8217;<a href=\"https:\/\/www.idae.es\/\">Instituto para la Diversificaci\u00f3n y Ahorro de la Energ\u00eda (IDAE)<\/a> en mat\u00e8ria d&#8217;efici\u00e8ncia i manteniment preventiu per a instal\u00b7lacions t\u00e8rmiques d&#8217;\u00fas dom\u00e8stic.<\/p>\n<p>A JAG Alcaide operem com a especialistes integrals en climatitzaci\u00f3 a tota Barcelona. Abordem aquest tipus de desajustos mec\u00e0nics i hidr\u00e0ulics aplicant m\u00e8todes de diagn\u00f2stic precisos i definitius. Entendre si la p\u00e8rdua de pressi\u00f3 es deu a un petit degoteig imperceptible al circuit, a una acumulaci\u00f3 d&#8217;aire que requereix purgar o a una fallada interna al vas d&#8217;expansi\u00f3 resulta vital per aportar solucions de calefacci\u00f3 veritablement segures. El nostre enfocament t\u00e8cnic es basa sempre a protegir la integritat del sistema a llarg termini i restablir el benestar absolut al domicili.<\/p>\n<h2>Qu\u00e8 significa l&#8217;error ALL 02 en una caldera Sime?<\/h2>\n<p>L&#8217;aparici\u00f3 d&#8217;un codi d&#8217;anomalia al panell digital de la calefacci\u00f3 acostuma a generar desconcert, per\u00f2 l&#8217;av\u00eds ALL 02 en els models del fabricant Sime \u00e9s, en realitat, un mecanisme d&#8217;autoprotecci\u00f3 molt definit. Aquest codi d&#8217;error indica que la caldera s&#8217;ha bloquejat de manera preventiva a causa d&#8217;una falta de pressi\u00f3 d&#8217;aigua al circuit primari de calefacci\u00f3. Sense el volum d&#8217;aigua suficient, l&#8217;equip no pot garantir una transmissi\u00f3 de calor segura ni una circulaci\u00f3 correcta, per la qual cosa interromp el seu funcionament per evitar avaries majors a l&#8217;intercanviador t\u00e8rmic.<\/p>\n<p>Perqu\u00e8 una caldera d&#8217;aquesta marca treballi en condicions \u00f2ptimes, la pressi\u00f3 del circuit en fred s&#8217;ha de situar sempre entre <strong>1,2 i 1,5 bar<\/strong>. Si l&#8217;indicador descendeix per sota del llindar cr\u00edtic dels <strong>0,5 bar<\/strong>, el press\u00f2stat d&#8217;aigua detecta l&#8217;anomalia i activa immediatament el bloqueig de seguretat. \u00c9s fonamental no confondre aquest senyal amb l&#8217;error ALL 03, el qual fa refer\u00e8ncia a un problema de sobretemperatura o a una fallada en el term\u00f2stat de fums, una incid\u00e8ncia de naturalesa totalment diferent que requereix comprovar l&#8217;evacuaci\u00f3 de gasos o l&#8217;estat de les sondes de temperatura i no la pressi\u00f3 de l&#8217;aigua.<\/p>\n<p>Resoldre aquesta incid\u00e8ncia de pressi\u00f3 pot requerir diferents nivells d&#8217;intervenci\u00f3 t\u00e8cnica segons l&#8217;origen exacte de la fallada:<\/p>\n<ul>\n<li><strong>Diagn\u00f2stic i purga del circuit:<\/strong> \u00datil per eliminar bosses d&#8217;aire acumulades i reajustar els nivells d&#8217;ompliment correctes. El cost d&#8217;aquest servei professional sol oscil\u00b7lar entre <strong>65\u20ac i 95\u20ac<\/strong>.<\/li>\n<li><strong>Substituci\u00f3 del press\u00f2stat d&#8217;aigua:<\/strong> Si la pe\u00e7a de mesura est\u00e0 danyada i realitza lectures falses fins i tot amb el circuit ple, el seu canvi se situa entre <strong>110\u20ac i 170\u20ac<\/strong>.<\/li>\n<li><strong>Reparaci\u00f3 o canvi del vas d&#8217;expansi\u00f3:<\/strong> Quan la pressi\u00f3 fluctua de manera descontrolada cada vegada que s&#8217;enc\u00e9n la calefacci\u00f3, la intervenci\u00f3 en aquest component varia entre <strong>180\u20ac i 290\u20ac<\/strong>.<\/li>\n<\/ul>\n<p>Mantenir vigilat el man\u00f2metre de manera peri\u00f2dica ajuda a prevenir que el sistema arribi a aquest estat d&#8217;aturada i perllonga la vida \u00fatil de la instal\u00b7laci\u00f3.<\/p>\n<h2>Com solucionar l&#8217;error ALL 02 pas a pas (Instruccions d&#8217;ompliment)<\/h2>\n<p>Retornar l&#8217;aigua necess\u00e0ria al circuit de calefacci\u00f3 \u00e9s un proc\u00e9s senzill que requereix precisi\u00f3 per evitar problemes majors per sobrepressi\u00f3.<\/p>\n<p>El primer pas consisteix a ubicar la clau d&#8217;ompliment. A la pr\u00e0ctica totalitat dels models de la marca Sime, aquesta petita aixeta de pl\u00e0stic (habitualment de color negre o blau) es troba a la part inferior de l&#8217;aparell, just a la zona on es connecten les canonades d&#8217;aigua i gas.<\/p>\n<p>Un cop identificada l&#8217;aixeta, la manipulaci\u00f3 s&#8217;ha de realitzar sempre amb la caldera freda i apagada:<\/p>\n<ul>\n<li>Gira la clau lentament en <strong>sentit contrari a les agulles del rellotge<\/strong>.<\/li>\n<li>Escoltar\u00e0s el so de l&#8217;aigua entrant al circuit de calefacci\u00f3.<\/li>\n<li>Mantingues la mirada fixa al man\u00f2metre de la caldera (l&#8217;indicador de pressi\u00f3, que pot ser una agulla f\u00edsica o un indicador digital a la pantalla).<\/li>\n<\/ul>\n<p>L&#8217;objectiu \u00e9s situar la pressi\u00f3 en un rang d&#8217;<strong>entre 1,2 i 1,5 bar<\/strong>. Tan aviat com l&#8217;agulla se situ\u00ef en aquesta zona \u00f2ptima, tanca l&#8217;aixeta amb fermesa girant-la en el sentit de les agulles del rellotge. \u00c9s summament important no sobrepassar els 2 bar de pressi\u00f3 en fred, ja que en escalfar-se l&#8217;aigua la pressi\u00f3 pujar\u00e0 de manera natural i podria activar-se la v\u00e0lvula de seguretat per exc\u00e9s de c\u00e0rrega.<\/p>\n<p>Un cop restablerta la pressi\u00f3 correcta, el codi d&#8217;error ALL 02 sol romandre actiu a la pantalla per seguretat. Per eliminar-lo i reactivar l&#8217;equip, gira el selector de comandaments principal de la caldera cap a la <strong>posici\u00f3 &#8220;R&#8221; (Reset)<\/strong>. Mantingues el comandament en aquesta posici\u00f3 durant uns tres segons i despr\u00e9s retorna&#8217;l al mode de funcionament habitual (hivern o estiu). El sistema realitzar\u00e0 un autodiagn\u00f2stic i el cremador es tornar\u00e0 a encendre amb total normalitat.<\/p>\n<h2>Causes per les quals la pressi\u00f3 torna a baixar i persisteix l&#8217;error ALL 02<\/h2>\n<p>Omplir el circuit de calefacci\u00f3 sembla la soluci\u00f3 m\u00e9s \u00f2bvia quan l&#8217;indicador marca un nivell baix, per\u00f2 el veritable desafiament sorgeix quan, al cap d&#8217;unes hores o dies, la pressi\u00f3 torna a caure en picat i el codi de bloqueig reapareix de manera sistem\u00e0tica. Aquest comportament c\u00edclic sol amagar anomalies internes que requereixen un diagn\u00f2stic t\u00e8cnic prec\u00eds.<\/p>\n<p>Les p\u00e8rdues d&#8217;aigua no sempre es manifesten com un gran bassal visible a terra. En molts habitatges de Barcelona, l&#8217;origen del problema es troba en juntes resseques, detentors desgastats o claus de radiador que degoten de manera gaireb\u00e9 imperceptible. Com que els tubs i radiadors estan calents, aquesta petita quantitat d&#8217;aigua s&#8217;evapora immediatament, dificultant la localitzaci\u00f3 visual de la fuga mentre el sistema continua perdent pressi\u00f3 de manera constant.<\/p>\n<p>El vas d&#8217;expansi\u00f3 \u00e9s l&#8217;encarregat d&#8217;absorbir l&#8217;augment de volum de l&#8217;aigua quan aquesta s&#8217;escalfa. Si la membrana interna del vas perd la c\u00e0rrega d&#8217;aire o es perfora, la pressi\u00f3 del circuit es dispara r\u00e0pidament en encendre la calefacci\u00f3. Per evitar danys estructurals, la v\u00e0lvula de seguretat de tres bars s&#8217;obre autom\u00e0ticament i expulsa l&#8217;exc\u00e9s d&#8217;aigua. Un cop la caldera es refreda, la pressi\u00f3 cau per sota del m\u00ednim, provocant de nou el bloqueig.<\/p>\n<p>El press\u00f2stat actua com el vigilant de la caldera, mesurant mec\u00e0nicament la pressi\u00f3 interna del circuit. Amb el pas del temps, aquest sensor acumula sediments o pateix un desgast en els seus contactes el\u00e8ctrics, cosa que li impedeix enviar el senyal correcte a la placa electr\u00f2nica. Encara que la pressi\u00f3 real de la instal\u00b7laci\u00f3 sigui l&#8217;adequada, un press\u00f2stat defectu\u00f3s registrar\u00e0 una lectura nul\u00b7la.<\/p>\n<p>L&#8217;acumulaci\u00f3 de cal\u00e7, molt habitual a causa de la duresa de l&#8217;aigua a l&#8217;\u00e0rea metropolitana, sol impedir que la clau d&#8217;ompliment tanqui de manera completament herm\u00e8tica, provocant inestabilitat i retorns d&#8217;aigua que alteren el correcte funcionament de la caldera.<\/p>\n<h2>Quan cal avisar un t\u00e8cnic de climatitzaci\u00f3 professional?<\/h2>\n<p>L&#8217;error ALL 02 en un equip Sime se sol resoldre de manera temporal restablint la pressi\u00f3 d&#8217;aigua, per\u00f2 existeixen escenaris on la intervenci\u00f3 d&#8217;un especialista esdev\u00e9 imprescindible per evitar avaries majors. L&#8217;indicador m\u00e9s clar que el problema requereix atenci\u00f3 professional ocorre quan la pressi\u00f3 cau a zero repetidament en q\u00fcesti\u00f3 de poques hores o dies despr\u00e9s d&#8217;haver omplert el circuit de calefacci\u00f3.<\/p>\n<p>Ignorar aquesta p\u00e8rdua constant d&#8217;aigua i limitar-se a omplir el sistema de manera sistem\u00e0tica comporta greus riscos. L&#8217;entrada cont\u00ednua d&#8217;aigua nova introdueix oxigen i minerals al circuit tancat, la qual cosa accelera la corrosi\u00f3 interna dels components met\u00e0l\u00b7lics de la caldera i obstrueix els radiadors amb fangs. A m\u00e9s, aquest comportament pot derivar en humitats ocultes a parets o terres, i sotmet la bomba de circulaci\u00f3 a un sobreesfor\u00e7 cr\u00edtic que pot acabar cremant el seu motor a causa del treball en sec o a la pres\u00e8ncia persistent d&#8217;aire al sistema.<\/p>\n<p>Per solucionar l&#8217;anomalia d&#8217;arrel, un t\u00e8cnic qualificat ha de realitzar un diagn\u00f2stic t\u00e8cnic dels components interns de l&#8217;aparell. Aquesta tasca implica el desmuntatge segur de la coberta per comprovar l&#8217;estat de la membrana del vas d&#8217;expansi\u00f3, verificar si la v\u00e0lvula de seguretat de tres bars presenta fugues per acumulaci\u00f3 de cal\u00e7, o avaluar l&#8217;estanquitat de l&#8217;intercanviador primari. En qualsevol d&#8217;aquestes situacions, la substituci\u00f3 de les peces desgastades s&#8217;ha de realitzar sempre amb recanvis oficials Sime, assegurant aix\u00ed que l&#8217;equip recuperi els seus nivells \u00f2ptims d&#8217;efici\u00e8ncia, rendiment i seguretat de funcionament.<\/p>\n<p>Restablir la pressi\u00f3 de l&#8217;aigua resulta, en la gran majoria dels casos, la mesura suficient per retornar la normalitat a un sistema de calefacci\u00f3 bloquejat per aquest av\u00eds. El codi ALL 02 a les calderes Sime actua com un mecanisme d&#8217;autoprotecci\u00f3 summament efica\u00e7, ja que atura immediatament el funcionament de l&#8217;equip abans que la falta de cabal pugui provocar un sobreescalfament cr\u00edtic en els components interns.<\/p>\n<p>Reposar el nivell d&#8217;aigua mitjan\u00e7ant la clau d&#8217;ompliment inferior \u00e9s una tasca de manteniment b\u00e0sic que el mateix usuari pot realitzar en pocs minuts. Aix\u00f2 no obstant, la situaci\u00f3 requereix un altre enfocament si aquesta fallada es manifesta de manera recurrent. Una caldera que perd pressi\u00f3 constantment alerta sobre una anomalia estructural al circuit tancat. L&#8217;origen de la descompensaci\u00f3 se sol trobar en microfugues ocultes a la instal\u00b7laci\u00f3, en una fallada del press\u00f2stat o en el trencament de la membrana del vas d&#8217;expansi\u00f3.<\/p>\n<p>Limitar-se a omplir el circuit de forma repetitiva \u00e9s un error greu; aquesta pr\u00e0ctica introdueix constantment aigua nova amb cal\u00e7 i oxigen a les canonades, accelerant la corrosi\u00f3 interna de tot el sistema. Davant d&#8217;un escenari de p\u00e8rdua cont\u00ednua, la intervenci\u00f3 especialitzada \u00e9s indispensable. Un diagn\u00f2stic professional i purga del circuit, el cost habitual del qual oscil\u00b7la entre els 65\u20ac i 95\u20ac, permet localitzar l&#8217;origen exacte de la fuga o de la fallada del sensor, evitant aix\u00ed avaries que requereixin la substituci\u00f3 de peces molt m\u00e9s costoses a curt termini.<\/p>\n<p>A JAG Alcaide som experts en el diagn\u00f2stic prec\u00eds i la reparaci\u00f3 integral de calderes i sistemes de calefacci\u00f3. El nostre equip t\u00e8cnic garanteix intervencions r\u00e0pides, resolutives i orientades a perllongar la vida \u00fatil dels teus equips amb total seguretat. Oferim cobertura professional per a solucions de climatitzaci\u00f3 a tota Barcelona i la seva \u00e0rea metropolitana. Confia en els nostres especialistes per retornar el confort a la teva llar i assegurar el m\u00e0xim rendiment energ\u00e8tic de la teva instal\u00b7laci\u00f3.<\/p>\n<div class=\"faq-section\" style=\"margin:32px 0\">\n<h2 style=\"font-size:22px;margin-bottom:16px\">Preguntas frecuentes<\/h2>\n<details style=\"border-bottom:1px solid #e0e0e0;padding:12px 0\">\n<summary style=\"font-weight:600;cursor:pointer;font-size:16px\">&#10067; Qu\u00e8 indica l&#8217;error ALL 02 a les calderes Sime?<\/summary>\n<p style=\"margin:8px 0 0 0;color:#444\">L&#8217;error ALL 02 indica una falta de pressi\u00f3 d&#8217;aigua al circuit primari de calefacci\u00f3 (generalment per sota dels 0,5 bar). \u00c9s un mecanisme d&#8217;autoprotecci\u00f3 que bloqueja la caldera per evitar avaries per sobreescalfament.<\/p>\n<\/details>\n<details style=\"border-bottom:1px solid #e0e0e0;padding:12px 0\">\n<summary style=\"font-weight:600;cursor:pointer;font-size:16px\">&#10067; A quina pressi\u00f3 ha d&#8217;estar una caldera Sime en fred?<\/summary>\n<p style=\"margin:8px 0 0 0;color:#444\">Per garantir un funcionament \u00f2ptim i segur, la pressi\u00f3 del circuit d&#8217;una caldera Sime en fred ha d&#8217;estar situada sempre entre 1,2 i 1,5 bar.<\/p>\n<\/details>\n<\/div>\n<div class=\"cta-box\" style=\"background:#f0f7ff;border-left:4px solid #0066cc;padding:20px;margin:30px 0;border-radius:4px\">\n<h3>\u00bfNecesitas ayuda profesional en Barcelona?<\/h3>\n<p>En <strong>JAG Alcaide<\/strong> te ofrecemos presupuesto sin compromiso. Nuestro equipo de profesionales est\u00e1 a tu disposici\u00f3n.<\/p>\n<p><a href=\"https:\/\/www.jagalcaide.com\/ca\/sollicitar-pressupost\/\" style=\"background:#0066cc;color:white;padding:10px 20px;text-decoration:none;border-radius:4px;display:inline-block\">Sol\u00b7licitar Pressupost Gratu\u00eft<\/a> | \ud83d\udcde <a href=\"tel:+34 616 946 678\">+34 616 946 678<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>En ple descens de les temperatures, la fiabilitat del confort t\u00e8rmic a la llar esdev\u00e9 una prioritat absoluta. Trobar el codi d&#8217;error &#8220;ALL 02&#8221; parpellejant al display d&#8217;una caldera Sime \u00e9s una situaci\u00f3 que genera [&hellip;]<\/p>\n","protected":false},"author":25,"featured_media":7191,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_yoast_wpseo_focuskw":"","_yoast_wpseo_title":"Caldera Sime Error ALL 02: Qu\u00e8 \u00e9s i com solucionar-ho","_yoast_wpseo_metadesc":"L'error ALL 02 a la teva caldera Sime indica una falta de pressi\u00f3. Descobreix com omplir el circuit pas a pas i quan avisar un t\u00e8cnic a Barcelona.","footnotes":""},"categories":[193],"tags":[],"class_list":["post-7195","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-otros"],"acf":[],"translation_of":5202,"jag_meta_title":"Caldera Sime Error ALL 02: Qu\u00e8 \u00e9s i com solucionar-ho","jag_meta_desc":"L'error ALL 02 a la teva caldera Sime indica una falta de pressi\u00f3. Descobreix com omplir el circuit pas a pas i quan avisar un t\u00e8cnic a Barcelona.","yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Caldera Sime Error ALL 02: Qu\u00e8 \u00e9s i com solucionar-ho<\/title>\n<meta name=\"description\" content=\"L&#039;error ALL 02 a la teva caldera Sime indica una falta de pressi\u00f3. Descobreix com omplir el circuit pas a pas i quan avisar un t\u00e8cnic a Barcelona.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/\" \/>\n<meta property=\"og:locale\" content=\"ca_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Caldera Sime Error ALL 02: Qu\u00e8 \u00e9s i com solucionar-ho\" \/>\n<meta property=\"og:description\" content=\"L&#039;error ALL 02 a la teva caldera Sime indica una falta de pressi\u00f3. Descobreix com omplir el circuit pas a pas i quan avisar un t\u00e8cnic a Barcelona.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/\" \/>\n<meta property=\"og:site_name\" content=\"JAG ALCAIDE \u2013 Instalaci\u00f3n, reparaci\u00f3n y mantenimiento en Barcelona\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-05T20:13:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-05T20:13:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.jagalcaide.com\/wp-content\/uploads\/2026\/06\/feat-boiler-repair-technician.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"608\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Raul Velazquez\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@JAGAlcaideSL\" \/>\n<meta name=\"twitter:site\" content=\"@JAGAlcaideSL\" \/>\n<meta name=\"twitter:label1\" content=\"Escrit per\" \/>\n\t<meta name=\"twitter:data1\" content=\"Raul Velazquez\" \/>\n\t<meta name=\"twitter:label2\" content=\"Temps estimat de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minuts\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/\"},\"author\":{\"name\":\"Raul Velazquez\",\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/#\\\/schema\\\/person\\\/eb81be1e846acf54a79015d674979fa4\"},\"headline\":\"Caldera Sime error ALL 02: Causes i solucions definitives\",\"datePublished\":\"2026-06-05T20:13:15+00:00\",\"dateModified\":\"2026-06-05T20:13:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/\"},\"wordCount\":2098,\"publisher\":{\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jagalcaide.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/feat-boiler-repair-technician.jpg\",\"articleSection\":[\"Otros\"],\"inLanguage\":\"ca\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/\",\"url\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/\",\"name\":\"Caldera Sime Error ALL 02: Qu\u00e8 \u00e9s i com solucionar-ho\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jagalcaide.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/feat-boiler-repair-technician.jpg\",\"datePublished\":\"2026-06-05T20:13:15+00:00\",\"dateModified\":\"2026-06-05T20:13:18+00:00\",\"description\":\"L'error ALL 02 a la teva caldera Sime indica una falta de pressi\u00f3. Descobreix com omplir el circuit pas a pas i quan avisar un t\u00e8cnic a Barcelona.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/#breadcrumb\"},\"inLanguage\":\"ca\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ca\",\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.jagalcaide.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/feat-boiler-repair-technician.jpg\",\"contentUrl\":\"https:\\\/\\\/www.jagalcaide.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/feat-boiler-repair-technician.jpg\",\"width\":1080,\"height\":608,\"caption\":\"Error ALL 02 en Calderas Sime: Qu\u00e9 Significa y C\u00f3mo Resolverlo | JAG Alcaide Barcelona\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/caldera-sime-error-all-02-solucio\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Caldera Sime error ALL 02: Causes i solucions definitives\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/#website\",\"url\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/\",\"name\":\"JAG Alcaide - Instalaci\u00f3n y reparaci\u00f3n de Aire Acondicionado y Calderas\",\"description\":\"Otro sitio realizado con WordPress\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ca\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/#organization\",\"name\":\"JAG Alcaide\",\"url\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ca\",\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.jagalcaide.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/logo-alcaide-gran.jpg\",\"contentUrl\":\"https:\\\/\\\/www.jagalcaide.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/logo-alcaide-gran.jpg\",\"width\":696,\"height\":696,\"caption\":\"JAG Alcaide\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/JAGAlcaideSL\",\"https:\\\/\\\/www.instagram.com\\\/jagalcaide\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/j-a-g-alcaide-s-l-\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/#\\\/schema\\\/person\\\/eb81be1e846acf54a79015d674979fa4\",\"name\":\"Raul Velazquez\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ca\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c1d39a6d7db56fa657e68f0e097b306e3d77c1abf633faa532a3c5ac95db701b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c1d39a6d7db56fa657e68f0e097b306e3d77c1abf633faa532a3c5ac95db701b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c1d39a6d7db56fa657e68f0e097b306e3d77c1abf633faa532a3c5ac95db701b?s=96&d=mm&r=g\",\"caption\":\"Raul Velazquez\"},\"url\":\"https:\\\/\\\/www.jagalcaide.com\\\/ca\\\/author\\\/raul\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Caldera Sime Error ALL 02: Qu\u00e8 \u00e9s i com solucionar-ho","description":"L'error ALL 02 a la teva caldera Sime indica una falta de pressi\u00f3. Descobreix com omplir el circuit pas a pas i quan avisar un t\u00e8cnic a Barcelona.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/","og_locale":"ca_ES","og_type":"article","og_title":"Caldera Sime Error ALL 02: Qu\u00e8 \u00e9s i com solucionar-ho","og_description":"L'error ALL 02 a la teva caldera Sime indica una falta de pressi\u00f3. Descobreix com omplir el circuit pas a pas i quan avisar un t\u00e8cnic a Barcelona.","og_url":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/","og_site_name":"JAG ALCAIDE \u2013 Instalaci\u00f3n, reparaci\u00f3n y mantenimiento en Barcelona","article_published_time":"2026-06-05T20:13:15+00:00","article_modified_time":"2026-06-05T20:13:18+00:00","og_image":[{"width":1080,"height":608,"url":"https:\/\/www.jagalcaide.com\/wp-content\/uploads\/2026\/06\/feat-boiler-repair-technician.jpg","type":"image\/jpeg"}],"author":"Raul Velazquez","twitter_card":"summary_large_image","twitter_creator":"@JAGAlcaideSL","twitter_site":"@JAGAlcaideSL","twitter_misc":{"Escrit per":"Raul Velazquez","Temps estimat de lectura":"10 minuts"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/#article","isPartOf":{"@id":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/"},"author":{"name":"Raul Velazquez","@id":"https:\/\/www.jagalcaide.com\/ca\/#\/schema\/person\/eb81be1e846acf54a79015d674979fa4"},"headline":"Caldera Sime error ALL 02: Causes i solucions definitives","datePublished":"2026-06-05T20:13:15+00:00","dateModified":"2026-06-05T20:13:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/"},"wordCount":2098,"publisher":{"@id":"https:\/\/www.jagalcaide.com\/ca\/#organization"},"image":{"@id":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jagalcaide.com\/wp-content\/uploads\/2026\/06\/feat-boiler-repair-technician.jpg","articleSection":["Otros"],"inLanguage":"ca"},{"@type":"WebPage","@id":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/","url":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/","name":"Caldera Sime Error ALL 02: Qu\u00e8 \u00e9s i com solucionar-ho","isPartOf":{"@id":"https:\/\/www.jagalcaide.com\/ca\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/#primaryimage"},"image":{"@id":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jagalcaide.com\/wp-content\/uploads\/2026\/06\/feat-boiler-repair-technician.jpg","datePublished":"2026-06-05T20:13:15+00:00","dateModified":"2026-06-05T20:13:18+00:00","description":"L'error ALL 02 a la teva caldera Sime indica una falta de pressi\u00f3. Descobreix com omplir el circuit pas a pas i quan avisar un t\u00e8cnic a Barcelona.","breadcrumb":{"@id":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/#breadcrumb"},"inLanguage":"ca","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/"]}]},{"@type":"ImageObject","inLanguage":"ca","@id":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/#primaryimage","url":"https:\/\/www.jagalcaide.com\/wp-content\/uploads\/2026\/06\/feat-boiler-repair-technician.jpg","contentUrl":"https:\/\/www.jagalcaide.com\/wp-content\/uploads\/2026\/06\/feat-boiler-repair-technician.jpg","width":1080,"height":608,"caption":"Error ALL 02 en Calderas Sime: Qu\u00e9 Significa y C\u00f3mo Resolverlo | JAG Alcaide Barcelona"},{"@type":"BreadcrumbList","@id":"https:\/\/www.jagalcaide.com\/ca\/caldera-sime-error-all-02-solucio\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.jagalcaide.com\/ca\/"},{"@type":"ListItem","position":2,"name":"Caldera Sime error ALL 02: Causes i solucions definitives"}]},{"@type":"WebSite","@id":"https:\/\/www.jagalcaide.com\/ca\/#website","url":"https:\/\/www.jagalcaide.com\/ca\/","name":"JAG Alcaide - Instalaci\u00f3n y reparaci\u00f3n de Aire Acondicionado y Calderas","description":"Otro sitio realizado con WordPress","publisher":{"@id":"https:\/\/www.jagalcaide.com\/ca\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.jagalcaide.com\/ca\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ca"},{"@type":"Organization","@id":"https:\/\/www.jagalcaide.com\/ca\/#organization","name":"JAG Alcaide","url":"https:\/\/www.jagalcaide.com\/ca\/","logo":{"@type":"ImageObject","inLanguage":"ca","@id":"https:\/\/www.jagalcaide.com\/ca\/#\/schema\/logo\/image\/","url":"https:\/\/www.jagalcaide.com\/wp-content\/uploads\/2023\/05\/logo-alcaide-gran.jpg","contentUrl":"https:\/\/www.jagalcaide.com\/wp-content\/uploads\/2023\/05\/logo-alcaide-gran.jpg","width":696,"height":696,"caption":"JAG Alcaide"},"image":{"@id":"https:\/\/www.jagalcaide.com\/ca\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/JAGAlcaideSL","https:\/\/www.instagram.com\/jagalcaide\/","https:\/\/www.linkedin.com\/company\/j-a-g-alcaide-s-l-"]},{"@type":"Person","@id":"https:\/\/www.jagalcaide.com\/ca\/#\/schema\/person\/eb81be1e846acf54a79015d674979fa4","name":"Raul Velazquez","image":{"@type":"ImageObject","inLanguage":"ca","@id":"https:\/\/secure.gravatar.com\/avatar\/c1d39a6d7db56fa657e68f0e097b306e3d77c1abf633faa532a3c5ac95db701b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c1d39a6d7db56fa657e68f0e097b306e3d77c1abf633faa532a3c5ac95db701b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c1d39a6d7db56fa657e68f0e097b306e3d77c1abf633faa532a3c5ac95db701b?s=96&d=mm&r=g","caption":"Raul Velazquez"},"url":"https:\/\/www.jagalcaide.com\/ca\/author\/raul\/"}]}},"wpml_current_locale":"ca","wpml_translations":{"en_US":{"locale":"en_US","id":7196,"slug":"sime-boiler-error-all-02-fix","post_title":"Sime Boiler Error ALL 02: What It Means and How to Fix It","href":"https:\/\/www.jagalcaide.com\/en\/sime-boiler-error-all-02-fix\/"},"es_ES":{"locale":"es_ES","id":7194,"slug":"caldera-sime-error-all-02","post_title":"Error ALL 02 en Calderas Sime: Qu\u00e9 Significa y C\u00f3mo Resolverlo","href":"https:\/\/www.jagalcaide.com\/caldera-sime-error-all-02\/"}},"_links":{"self":[{"href":"https:\/\/www.jagalcaide.com\/ca\/wp-json\/wp\/v2\/posts\/7195","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jagalcaide.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jagalcaide.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jagalcaide.com\/ca\/wp-json\/wp\/v2\/users\/25"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jagalcaide.com\/ca\/wp-json\/wp\/v2\/comments?post=7195"}],"version-history":[{"count":0,"href":"https:\/\/www.jagalcaide.com\/ca\/wp-json\/wp\/v2\/posts\/7195\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jagalcaide.com\/ca\/wp-json\/wp\/v2\/media\/7191"}],"wp:attachment":[{"href":"https:\/\/www.jagalcaide.com\/ca\/wp-json\/wp\/v2\/media?parent=7195"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jagalcaide.com\/ca\/wp-json\/wp\/v2\/categories?post=7195"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jagalcaide.com\/ca\/wp-json\/wp\/v2\/tags?post=7195"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}